Electric Eccentric Control Valve Product Features
(1) Low fluid resistance; full-bore electric ball valves exhibit virtually no flow obstruction.
(2) Simple structure, compact size, and lightweight design.
(3) Tight and reliable sealing. Featuring two sealing surfaces, modern ball valves widely utilize various plastics for these surfaces, ensuring excellent sealing performance and achieving complete sealing. They are also extensively used in vacuum systems.
(4) Easy operation with rapid opening/closing. A 90° rotation completes the full-open to full-close cycle, facilitating remote control.
(5) Simple maintenance. The straightforward valve structure features removable seals, allowing easy disassembly and replacement.
(6) When fully open or closed, the sealing surfaces of the ball and seat are isolated from the medium. This prevents erosion of the valve sealing surfaces during medium flow.
(7) Wide applicability: Sizes range from a few millimeters to several meters in diameter, suitable for applications from high vacuum to high pressure.
(8) Due to the wiping action during opening and closing, electric eccentric control valves can be used with media containing suspended solid particles.
Electric Eccentric Control Valve Key Technical Parameters and Performance Specifications
| Nominal Diameter DN(mm) | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 |
|---|
Rated Flow Coefficient KV | Full-cavity type | 14 | 25 | 30 | 55 | 100 | 135 | 230 | 320 | 500 | 850 | 1300 | 1750 |
| 60% cavity type | - | - | - | - | - | - | - | - | 300 | 510 | 780 | 1050 |
| 40% cavity type | 6 | 10 | 12 | 20 | 40 | 54 | 92 | 128 | 200 | 340 | 520 | 700 |
| Allowable Differential Pressure (MPa) | ≤Nominal Pressure |
| Valve Body Type | Integrally cast spherical body |
| Valve Core Type | Eccentric Rotary Spool (with Flow Guide Wings) |
| Flow Characteristics | Approximately equal percentage |
| Range of motion | Fully open 60° |
| Leakage rate Q | Soft-sealed Class VI, hard-sealed Class IV, compliant with ANSI B16.104 standard |
| Basic error | ±1% |
| Hysteresis | ±1% |
| Dead zone | ≤1% |
| Adjustable range | Full cavity type (100:1), 60% cavity type (60:1), 40% cavity type (40:1) |
| Configure the actuator | Compatible with PSQ, HQ, UNIC, 361RS, JO, and other series of quarter-turn electric actuators |
| Control Method | Switch Position Indicator (two-position control), Passive Contact Signal, 1/5K Potentiometer, Intelligent Adjustment (4-20mA Analog Signal Control) |
Tianjin Yibiao Valves Main Products: